category: 063
edition: 1.6
date: 2020-08-04
Surveillance data exchange.
I063/010 - Data Source Identifier
definition: Identification of the radar station from which the data are received.
Group
I063/010/SAC - System Area Code
Element
bit size: 8
Raw Content
I063/010/SIC - System Identification Code
Element
bit size: 8
Raw Content
- Note:
The defined SACs are on the EUROCONTROL ASTERIX website (www.eurocontrol.int/asterix)
I063/015 - Service Identification
definition: Identification of the service provided to one or more users.
Element
bit size: 8
Raw Content
The service identification is allocated by the SDPS
I063/030 - Time of Message
definition: Absolute time stamping of the message, in the form of elapsed time since last midnight, expressed as UTC.
Element
bit size: 24
Unsigned quantity
LSB = 1/27 s ≈ 7.8125e − 3 s
unit: "s"
The time of the day value is reset to zero at every midnight.
I063/050 - Sensor Identifier
Group
I063/050/SAC - System Area Code
Element
bit size: 8
Raw Content
I063/050/SIC - System Identification Code
Element
bit size: 8
Raw Content
- The up-to-date list of SACs is published on the EUROCONTROL Web Site (http://www.eurocontrol.int/asterix).
- If the SAC/SIC refers to an SDPS used as input, the respective sensor status information will be transmitted using the Reserved Expansion Field.
I063/060 - Sensor Configuration and Status
definition: Configuration and status of the sensor
Extended
I063/060/CON
Element
bit size: 2
Values:
0
:- Operational
1
:- Degraded
2
:- Initialization
3
:- Not currently connected
I063/060/PSR
Element
bit size: 1
Values:
0
:- PSR GO
1
:- PSR NOGO
I063/060/SSR
Element
bit size: 1
Values:
0
:- SSR GO
1
:- SSR NOGO
I063/060/MDS
Element
bit size: 1
Values:
0
:- MDS GO
1
:- MDS NOGO
I063/060/ADS
Element
bit size: 1
Values:
0
:- ADS GO
1
:- ADS NOGO
I063/060/MLT
Element
bit size: 1
Values:
0
:- MLT GO
1
:- MLT NOGO
(FX) - extension bit
I063/060/OPS - Operational Release Status of the System
Element
bit size: 1
Values:
0
:- System is released for operational use
1
:- Operational use of System is inhibited
I063/060/ODP - Data Processor Overload Indicator
Element
bit size: 1
Values:
0
:- Default, no overload
1
:- Overload in DP
I063/060/OXT - Transmission Subsystem Overload Status
Element
bit size: 1
Values:
0
:- Default, no overload
1
:- Overload in transmission subsystem
I063/060/MSC - Monitoring System Connected Status
Element
bit size: 1
Values:
0
:- Monitoring system connected
1
:- Monitoring system disconnected
I063/060/TSV - Time Source Validity
Element
bit size: 1
Values:
0
:- Valid
1
:- Invalid
I063/060/NPW - No Plot Warning
Element
bit size: 1
Values:
0
:- Default (no meaning)
1
:- No plots being received
Spare bits: 1
(FX) - extension bit
- GO/NOGO information from PSR, SSR, Mode S, ADS and MLT is derived from monosensor categories and has a meaning only for operational sensors, whereas (CON) is derived by the SDPS.
- The information (OPS), (ODP), (OXT), (MSC) and (TSV) are only related to CNS/ATM Ground Station and are derived from monosensor category (ASTERIX Cat 023).
I063/070 - Time Stamping Bias
definition: Plot Time stamping bias, in two’s complement form
Element
bit size: 16
Signed quantity
LSB = 1 ms ≈ 1.0 ms
unit: "ms"
I063/080 - SSR / Mode S Range Gain and Bias
definition: SSR / Mode S Range Gain and Range Bias, in two’s complement form.
Group
I063/080/SRG - Mode S Range Gain
Element
bit size: 16
Signed quantity
LSB = 1/100000 ≈ 1.0e − 5
unit: ""
I063/080/SRB - Mode S Range Bias
Element
bit size: 16
Signed quantity
LSB = 1/27 NM ≈ 7.8125e − 3 NM
unit: "NM"
Note:
The following formula is used to correct range:
$$\rho_\mathrm{corrected} = \frac{\rho_\mathrm{measured} - range\_bias}{1 + range\_gain}$$
I063/081 - SSR Mode S Azimuth Bias
definition: SSR / Mode S Azimuth Bias, in two’s complement form.
Element
bit size: 16
Signed quantity
LSB = 360/216 ° ≈ 5.4931640625e − 3 °
unit: "°"
Note:
The following formula is used to correct azimuth:
θcorrected = θmeasured − azimuth_bias
I063/090 - PSR Range Gain and Bias
definition: PSR Range Gain and PSR Range Bias, in two’s complement form.
Group
I063/090/PRG - PSR Range Gain
Element
bit size: 16
Signed quantity
LSB = 1/100000 ≈ 1.0e − 5
unit: ""
I063/090/PRB - PSR Range Bias
Element
bit size: 16
Signed quantity
LSB = 1/27 NM ≈ 7.8125e − 3 NM
unit: "NM"
Note:
The following formula is used to correct range:
rhomathrm{corrected} = frac{rhomathrm{measured} - range_bias}{1 + range_gain}
I063/091 - PSR Azimuth Bias
definition: PSR Azimuth Bias, in two’s complement form.
Element
bit size: 16
Signed quantity
LSB = 360/216 ° ≈ 5.4931640625e − 3 °
unit: "°"
Note:
The following formula is used to correct azimuth:
θcorrected = θmeasured − azimuth_bias
I063/092 - PSR Elevation Bias
definition: PSR Elevation Bias, in two’s complement form.
Element
bit size: 16
Signed quantity
LSB = 360/216 ° ≈ 5.4931640625e − 3 °
unit: "°"
I063/RE - Reserved Expansion Field
definition: Expansion
Explicit (ReservedExpansion)
I063/SP - Special Purpose Field
definition: Special Purpose Field
Explicit (SpecialPurpose)
I063/010
- Data Source IdentifierI063/015
- Service IdentificationI063/030
- Time of MessageI063/050
- Sensor IdentifierI063/060
- Sensor Configuration and StatusI063/070
- Time Stamping BiasI063/080
- SSR / Mode S Range Gain and BiasI063/081
- SSR Mode S Azimuth BiasI063/090
- PSR Range Gain and BiasI063/091
- PSR Azimuth BiasI063/092
- PSR Elevation BiasI063/RE
- Reserved Expansion FieldI063/SP
- Special Purpose Field