Asterix category 063 - Sensor Status Reports
category: 063
edition: 1.6
date: 2020-08-04
Preamble
Surveillance data exchange.
Description of standard data items
I063/010 - Data Source Identifier
Definition: Identification of the radar station from which the data are received.
Structure:
I063/010/SAC - System Area Code
- 8 bits [
........
]- raw value
I063/010/SIC - System Identification Code
- 8 bits [
........
]- raw value
- Note:
-
The defined SACs are on the EUROCONTROL ASTERIX website (www.eurocontrol.int/asterix)
I063/015 - Service Identification
Definition: Identification of the service provided to one or more users.
Structure:
- 8 bits [
........
] - raw value
The service identification is allocated by the SDPS
I063/030 - Time of Message
Definition: Absolute time stamping of the message, in the form of elapsed time since last midnight, expressed as UTC.
Structure:
- 24 bits [
........................
] - unsigned quantity
- unit: “s”
- LSB = 1/27 s ≈ 7.81e − 3 s
The time of the day value is reset to zero at every midnight.
I063/050 - Sensor Identifier
Definition: Structure:
I063/050/SAC - System Area Code
- 8 bits [
........
]- raw value
I063/050/SIC - System Identification Code
- 8 bits [
........
]- raw value
- The up-to-date list of SACs is published on the EUROCONTROL Web Site (http://www.eurocontrol.int/asterix).
- If the SAC/SIC refers to an SDPS used as input, the respective sensor status information will be transmitted using the Reserved Expansion Field.
I063/060 - Sensor Configuration and Status
Definition: Configuration and status of the sensor
Structure:
Extended item.
I063/060/CON
2 bits [
..
]values:
0: Operational
1: Degraded
2: Initialization
3: Not currently connectedI063/060/PSR
1 bit [
.
]values:
0: PSR GO
1: PSR NOGOI063/060/SSR
1 bit [
.
]values:
0: SSR GO
1: SSR NOGOI063/060/MDS
1 bit [
.
]values:
0: MDS GO
1: MDS NOGOI063/060/ADS
1 bit [
.
]values:
0: ADS GO
1: ADS NOGOI063/060/MLT
1 bit [
.
]values:
0: MLT GO
1: MLT NOGO
(FX)
extension bit
0: End of data item
1: Extension into next extentI063/060/OPS - Operational Release Status of the System
1 bit [
.
]values:
0: System is released for operational use
1: Operational use of System is inhibitedI063/060/ODP - Data Processor Overload Indicator
1 bit [
.
]values:
0: Default, no overload
1: Overload in DPI063/060/OXT - Transmission Subsystem Overload Status
1 bit [
.
]values:
0: Default, no overload
1: Overload in transmission subsystemI063/060/MSC - Monitoring System Connected Status
1 bit [
.
]values:
0: Monitoring system connected
1: Monitoring system disconnectedI063/060/TSV - Time Source Validity
1 bit [
.
]values:
0: Valid
1: InvalidI063/060/NPW - No Plot Warning
1 bit [
.
]values:
0: Default (no meaning)
1: No plots being receivedI063/060/(spare)
- 1 bit [
.
]
(FX)
extension bit
0: End of data item
1: Extension into next extent
- GO/NOGO information from PSR, SSR, Mode S, ADS and MLT is derived from monosensor categories and has a meaning only for operational sensors, whereas (CON) is derived by the SDPS.
- The information (OPS), (ODP), (OXT), (MSC) and (TSV) are only related to CNS/ATM Ground Station and are derived from monosensor category (ASTERIX Cat 023).
I063/070 - Time Stamping Bias
Definition: Plot Time stamping bias, in two’s complement form
Structure:
- 16 bits [
................
] - signed quantity
- unit: “ms”
- LSB = 1 ms
I063/080 - SSR / Mode S Range Gain and Bias
Definition: SSR / Mode S Range Gain and Range Bias, in two’s complement form.
Structure:
I063/080/SRG - Mode S Range Gain
- 16 bits [
................
]- signed quantity
- LSB = 1/100000 ≈ 1.00e − 5
I063/080/SRB - Mode S Range Bias
- 16 bits [
................
]- signed quantity
- unit: “NM”
- LSB = 1/27 NM ≈ 7.81e − 3 NM
Note:
The following formula is used to correct range:
$$\rho_\mathrm{corrected} = \frac{\rho_\mathrm{measured} - range\_bias}{1 + range\_gain}$$
I063/081 - SSR Mode S Azimuth Bias
Definition: SSR / Mode S Azimuth Bias, in two’s complement form.
Structure:
- 16 bits [
................
] - signed quantity
- unit: “°”
- LSB = 360/216 ° ≈ 5.49e − 3 °
Note:
The following formula is used to correct azimuth:
θcorrected = θmeasured − azimuth_bias
I063/090 - PSR Range Gain and Bias
Definition: PSR Range Gain and PSR Range Bias, in two’s complement form.
Structure:
I063/090/PRG - PSR Range Gain
- 16 bits [
................
]- signed quantity
- LSB = 1/100000 ≈ 1.00e − 5
I063/090/PRB - PSR Range Bias
- 16 bits [
................
]- signed quantity
- unit: “NM”
- LSB = 1/27 NM ≈ 7.81e − 3 NM
Note:
The following formula is used to correct range:
rhomathrm{corrected} = frac{rhomathrm{measured} - range_bias}{1 + range_gain}
I063/091 - PSR Azimuth Bias
Definition: PSR Azimuth Bias, in two’s complement form.
Structure:
- 16 bits [
................
] - signed quantity
- unit: “°”
- LSB = 360/216 ° ≈ 5.49e − 3 °
Note:
The following formula is used to correct azimuth:
θcorrected = θmeasured − azimuth_bias
I063/092 - PSR Elevation Bias
Definition: PSR Elevation Bias, in two’s complement form.
Structure:
- 16 bits [
................
] - signed quantity
- unit: “°”
- LSB = 360/216 ° ≈ 5.49e − 3 °
I063/RE - Reserved Expansion Field
Definition: Expansion
Structure:
Explicit item (RE)
I063/SP - Special Purpose Field
Definition: Special Purpose Field
Structure:
Explicit item (SP)
User Application Profile for Category 063
I063/010
- Data Source Identifier
I063/015
- Service Identification
I063/030
- Time of Message
I063/050
- Sensor Identifier
I063/060
- Sensor Configuration and Status
I063/070
- Time Stamping Bias
I063/080
- SSR / Mode S Range Gain and Bias
(FX)
- Field extension indicatorI063/081
- SSR Mode S Azimuth Bias
I063/090
- PSR Range Gain and Bias
I063/091
- PSR Azimuth Bias
I063/092
- PSR Elevation Bias
(spare)
I063/RE
- Reserved Expansion Field
I063/SP
- Special Purpose Field
(FX)
- Field extension indicator