asterix 063 "Sensor Status Reports" edition 1.6 date 2020-08-04 preamble Surveillance data exchange. items 010 "Data Source Identifier" definition Identification of the radar station from which the data are received. group SAC "System Area Code" element 8 raw SIC "System Identification Code" element 8 raw remark Note: The defined SACs are on the EUROCONTROL ASTERIX website (www.eurocontrol.int/asterix) 015 "Service Identification" definition Identification of the service provided to one or more users. element 8 raw remark The service identification is allocated by the SDPS 030 "Time of Message" definition Absolute time stamping of the message, in the form of elapsed time since last midnight, expressed as UTC. element 24 unsigned quantity 1/2^7 "s" remark The time of the day value is reset to zero at every midnight. 050 "Sensor Identifier" group SAC "System Area Code" element 8 raw SIC "System Identification Code" element 8 raw remark - The up-to-date list of SACs is published on the EUROCONTROL Web Site (http://www.eurocontrol.int/asterix). - If the SAC/SIC refers to an SDPS used as input, the respective sensor status information will be transmitted using the Reserved Expansion Field. 060 "Sensor Configuration and Status" definition Configuration and status of the sensor extended CON "" element 2 table 0: Operational 1: Degraded 2: Initialization 3: Not currently connected PSR "" element 1 table 0: PSR GO 1: PSR NOGO SSR "" element 1 table 0: SSR GO 1: SSR NOGO MDS "" element 1 table 0: MDS GO 1: MDS NOGO ADS "" element 1 table 0: ADS GO 1: ADS NOGO MLT "" element 1 table 0: MLT GO 1: MLT NOGO - OPS "Operational Release Status of the System" element 1 table 0: System is released for operational use 1: Operational use of System is inhibited ODP "Data Processor Overload Indicator" element 1 table 0: Default, no overload 1: Overload in DP OXT "Transmission Subsystem Overload Status" element 1 table 0: Default, no overload 1: Overload in transmission subsystem MSC "Monitoring System Connected Status" element 1 table 0: Monitoring system connected 1: Monitoring system disconnected TSV "Time Source Validity" element 1 table 0: Valid 1: Invalid NPW "No Plot Warning" element 1 table 0: Default (no meaning) 1: No plots being received spare 1 - remark 1. GO/NOGO information from PSR, SSR, Mode S, ADS and MLT is derived from monosensor categories and has a meaning only for operational sensors, whereas (CON) is derived by the SDPS. 2. The information (OPS), (ODP), (OXT), (MSC) and (TSV) are only related to CNS/ATM Ground Station and are derived from monosensor category (ASTERIX Cat 023). 070 "Time Stamping Bias" definition Plot Time stamping bias, in two’s complement form element 16 signed quantity 1 "ms" 080 "SSR / Mode S Range Gain and Bias" definition SSR / Mode S Range Gain and Range Bias, in two’s complement form. group SRG "Mode S Range Gain" element 16 signed quantity 1/100000 "" SRB "Mode S Range Bias" element 16 signed quantity 1/2^7 "NM" remark Note: The following formula is used to correct range: .. math:: \rho_\mathrm{corrected} = \frac{\rho_\mathrm{measured} - range\_bias}{1 + range\_gain} 081 "SSR Mode S Azimuth Bias" definition SSR / Mode S Azimuth Bias, in two’s complement form. element 16 signed quantity 360/2^16 "°" remark Note: The following formula is used to correct azimuth: .. math:: \theta_\mathrm{corrected} = \theta_\mathrm{measured} - azimuth\_bias 090 "PSR Range Gain and Bias" definition PSR Range Gain and PSR Range Bias, in two’s complement form. group PRG "PSR Range Gain" element 16 signed quantity 1/100000 "" PRB "PSR Range Bias" element 16 signed quantity 1/2^7 "NM" remark Note: The following formula is used to correct range: .. math: \rho_\mathrm{corrected} = \frac{\rho_\mathrm{measured} - range\_bias}{1 + range\_gain} 091 "PSR Azimuth Bias" definition PSR Azimuth Bias, in two’s complement form. element 16 signed quantity 360/2^16 "°" remark Note: The following formula is used to correct azimuth: .. math:: \theta_\mathrm{corrected} = \theta_\mathrm{measured} - azimuth\_bias 092 "PSR Elevation Bias" definition PSR Elevation Bias, in two’s complement form. element 16 signed quantity 360/2^16 "°" RE "Reserved Expansion Field" definition Expansion explicit re SP "Special Purpose Field" definition Special Purpose Field explicit sp uap 010 015 030 050 060 070 080 081 090 091 092 - RE SP