category: 065
edition: 1.5
date: 2020-06-18
Surveillance data exchange.
I065/000 - Message Type
definition: This Data Item allows for a more convenient handling of the messages at the receiver side by further defining the type of transaction.
Element
bit size: 8
Values:
1
:- SDPS Status
2
:- End of Batch
3
:- Service Status Report
- Notes:
- In application where transactions of various types are exchanged, the Message Type Data Item facilitates the proper message handling at the receiver side.
I065/010 - Data Source Identifier
definition: Identification of the system sending the data.
Group
I065/010/SAC - System Area Code
Element
bit size: 8
Raw Content
I065/010/SIC - System Identification Code
Element
bit size: 8
Raw Content
- Note:
- The up-to-date list of SACs is published on the EUROCONTROL Web Site (http://www.eurocontrol.int/asterix).
I065/015 - Service Identification
definition: Identification of the service provided to one or more users.
Element
bit size: 8
Raw Content
- Note:
- The service identification is allocated by the SDPS.
I065/020 - Batch Number
definition: A number indicating the completion of a service for that batch of track data, from 0 to N-1, N being the number of batches used to make one complete processing cycle.
Element
bit size: 8
Unsigned integer
I065/030 - Time of Message
definition: Absolute time stamping of the message, in the form of elapsed time since last midnight, expressed as UTC.
Element
bit size: 24
Unsigned quantity
LSB = 1/27 s ≈ 7.8125e − 3 s
unit: "s"
- Note:
- The time is reset to zero at every midnight.
I065/040 - SDPS Configuration and Status
definition: Status of an SDPS.
Group
I065/040/NOGO
Element
bit size: 2
Values:
0
:- Operational
1
:- Degraded
2
:- Not currently connected
3
:- Unknown
I065/040/OVL
Element
bit size: 1
Values:
0
:- Default
1
:- Overload
I065/040/TSV
Element
bit size: 1
Values:
0
:- Default
1
:- Invalid Time Source
I065/040/PSS - Processing System Status
Element
bit size: 2
Values:
0
:- Not applicable
1
:- SDPS-1 selected
2
:- SDPS-2 selected
3
:- SDPS-3 selected
I065/040/STTN - Track Re-numbering Indication
Element
bit size: 1
Raw Content
The STTN bit indicates when track numbering has been restarted. The STTN bit is a toggle bit that changes its value whenever the SDPS system starts re-numbering its tracks. Re-numbering of the track takes place either after SDPS start-up (cold or hot start-up) or when a configuration set has been changed (please note that the latter case is ARTAS specific behaviour and may be different in another SDPS).
Spare bits: 1
I065/050 - Service Status Report
definition: Report sent by the SDPS related to a service
Element
bit size: 8
Values:
1
:- Service degradation
2
:- Service degradation ended
3
:- Main radar out of service
4
:- Service interrupted by the operator
5
:- Service interrupted due to contingency
6
:- Ready for service restart after contingency
7
:- Service ended by the operator
8
:- Failure of user main radar
9
:- Service restarted by the operator
10
:- Main radar becoming operational
11
:- Main radar becoming degraded
12
:- Service continuity interrupted due to disconnection with adjacent unit
13
:- Service continuity restarted
14
:- Service synchronised on backup radar
15
:- Service synchronised on main radar
16
:- Main and backup radar, if any, failed
I065/RE - Reserved Expansion Field
definition: Expansion
Explicit (ReservedExpansion)
I065/SP - Special Purpose Field
definition: Special Purpose Field
Explicit (SpecialPurpose)
I065/010
- Data Source IdentifierI065/000
- Message TypeI065/015
- Service IdentificationI065/030
- Time of MessageI065/020
- Batch NumberI065/040
- SDPS Configuration and StatusI065/050
- Service Status ReportI065/RE
- Reserved Expansion FieldI065/SP
- Special Purpose Field